241 West 132nd Street in Central Harlem, Manhattan, has 29 open HPD violations, 4 of them class C, and no rent-stabilized units are on its tax bill, as of Oct 26, 2026. StreetSpy grade: D (55/100).
Multi-family walk-up · 3 units · Built 1910
StreetSpy grade: D (Poor, 55/100)
- 4 immediately hazardous violations open (the class that covers no heat, pests, lead paint and similar).
- 1 open violation is classified rent-impairing under NY Multiple Dwelling Law section 302-a.
- No housing complaints to 311 in the last 12 months.
- No rent-stabilized units on the tax bill. Increases aren't capped by stabilization, though Good Cause Eviction may still limit them.
More open violations per unit than 9 in 10 Manhattan buildings this size.
- Repairs: High (29 open, 4 class C), records as of Oct 26, 2026
- Heat and hot water: No complaints, 12 mo, records as of Oct 25, 2026
- Pests: Clear (No bedbug filing, 3 yr), records as of Oct 28, 2026
- Safety: Clear (No open DOB violations), records as of Oct 26, 2026
- Registration: Expired Sep 1, 2023, records as of Oct 3, 2026
Housing code violations (HPD)
29 open violations: 4 class C (immediately hazardous), 5 class B, 17 class A, 3 class I (HPD orders such as lead paint or heat orders, not a hazard class). 1 issued in the last 12 months. 38 on record. Oldest open violation issued 2015-08-12. Newest violation issued 2026-04-29.
HPD recorded no violation closed here in the last 12 months.
1 open violation is classified rent-impairing under NY Multiple Dwelling Law section 302-a. Section 302-a; NY Courts guidance on getting repairs.
- Class C: No heat / heating defect (hallway). POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM MISSING AT PUBLIC HALL, 1st STORY, issued 2024-06-03. HPD violation 17011258
- Class C: No hot water, bathroom. D26-17.07 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES 2ND STY COMMUNITY BATHROOM BATHTUB., issued 2015-08-12. HPD violation 3088302
- Class C: No heat / heating defect (basement). D26-17.10 ADM CODE PROVIDE READY ACCESS TO BUILDING'S HEATING SYSTEM BOILER ROOM DOOR LOCKED AT CELLAR., issued 2015-08-12. HPD violation 3088304
- Class C: No heat / heating defect (hallway). D26-17.10 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDING'S HEATING SYSTEM 1ST STY PUBLIC HALL NEAR MAILBOXES AND AT DOOR TO BOILER ROOM., issued 2015-08-12. HPD violation 3088303
- Class B: Missing or broken smoke / CO detector, throughout the apartment, 2nd floor. HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST (apt 2), issued 2024-06-03. HPD violation 17011252
- Class B: Missing or broken smoke / CO detector, throughout the apartment, 2nd floor. REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 2, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST (apt 2), issued 2024-06-03. HPD violation 17011253
- Class B: Lighting defect (entrance). PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING MINIMUM OF 100 WATTS AS REQUIRED(LIGHT FIXTURE(S) PRESENT). AT FRONT AREAWAY, issued 2017-10-20. HPD violation 12024875
- Class B: No heat / heating defect (basement). SECTION 65 M/D LAW PROVIDE UNDER COMPLETED PERMIT, A PROPER ENCLOSURE FOR THE CENTRAL HEATING PLANT, AT CELLAR CENTER., issued 2015-08-12. HPD violation 3088293
311 housing complaints
0 in the last 12 months, 1 in 5 years.
Bedbugs
No bedbug filing on record for the last 3 years. HPD's bedbug filings are self-reported by the owner once a year; HPD does not inspect to confirm them.
- 2026: No bedbug filing on record for this year
- 2025: No bedbug filing on record for this year
- 2024: No bedbug filing on record for this year
- 2023: No bedbug filing on record for this year
- 2022: No bedbug filing on record for this year
- 2021: No bedbug filing on record for this year
Buildings department (DOB)
No open DOB violations. 5 DOB violations on record. Check on DOB BIS.
Evictions and housing court
0 executed evictions in the last 3 years (0 on record). 0 open HPD cases; 0 harassment findings.
Rent stabilization
No rent-stabilized units on the tax bill.
Owner and management
Owner: HENRY CONNELL. See the full portfolio.
Last HPD registration Mar 15, 2023. HPD registration expired Sep 1, 2023 and had not been renewed as of Oct 3, 2026. Buildings with 3+ units must register with HPD every year.
Tax lot and city IDs
BBL 1019380017, HPD building ID 40474. HPD Online, ACRIS, DOB BIS.
Nearest subway
- 135 St (C, B), 5 min walk
- 135 St (2, 3), 6 min walk
- 125 St (A, C, B, D), 8 min walk
How the grade is calculated
| Factor | On record | Points |
|---|---|---|
| Open HPD violations | 29 open (4 class C, 5 class B, 17 class A, 3 class I). 1 rent-impairing | −45 |
| 311 housing complaints (12 mo) | None | 0 |
| Bedbug reports (3 yr) | None reported | 0 |
| Executed evictions (3 yr) | None | 0 |
| Housing litigation | No open cases | 0 |
| Open DOB violations | None | 0 |
Sources: NYC HPD Housing Maintenance Code Violations, NYC 311 Service Requests, NYC HPD Bedbug Reporting, NYC Marshal Evictions (DOI), NYC HPD Housing Litigations, NYC DOB Violations, NYC DOF tax bills (via JustFix Who Owns What portfolio API, v2), NYC HPD Property Registration. Methodology. Report generated 2026-10-28.