111-12 Merrick Boulevard
111-12 Merrick Boulevard in South Jamaica, Queens, has 14 open HPD violations, 1 of them class C, and no rent-stabilized units are on its tax bill, as of Oct 25, 2026. StreetSpy grade: D (55/100).
Mixed residential & commercial · 2 units · Built 1935
StreetSpy grade: D (Poor, 55/100)
- 1 immediately hazardous violation open (the class that covers no heat, pests, lead paint and similar).
- 3 open violations are classified rent-impairing under NY Multiple Dwelling Law section 302-a.
- The owner has 2 buildings on record; 2 graded D or F.
- No rent-stabilized units on the tax bill. Increases aren't capped by stabilization, though Good Cause Eviction may still limit them.
- Repairs: High (14 open, 1 class C), records as of Oct 25, 2026
- Heat and hot water: No complaints, 12 mo, records as of Oct 25, 2026
- Pests: Clear (No bedbug filing, 3 yr), records as of Oct 27, 2026
- Safety: Clear (No open DOB violations), records as of Oct 23, 2026
- Registration: Expired Sep 1, 2019, records as of Oct 3, 2026
Housing code violations (HPD)
14 open violations: 1 class C (immediately hazardous), 7 class B, 6 class A. 1 issued in the last 12 months. 25 on record. Oldest open violation issued 2007-09-05. Newest violation issued 2026-05-07.
HPD recorded no violation closed here in the last 12 months.
3 open violations are classified rent-impairing under NY Multiple Dwelling Law section 302-a. Section 302-a; NY Courts guidance on getting repairs.
- Class C: No hot water, throughout the apartment, 2nd floor. PROVIDE ADEQUATE SUPPLY OF HOT WATER FOR THE FIXTURES KITCHEN AND BATHROOM ER-1 IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY (apt 2R), issued 2007-09-05. HPD violation 4480146
- Class B: Gas defect, bathroom, 2nd floor. REPAIR BY CLOSING SO AS TO BE GAS TIGHT ALL OPENINGS IN THE WASTE LINE OF WASH BASIN IN THE BATHROOM LOCATED AT APT 2R, 2nd STORY (apt 2R), issued 2007-09-05. HPD violation 4480058
- Class B: Door, lock or intercom defect, 2nd floor. PROPERLY REPAIR THE BROKEN OR DEFECTIVE ENTRANCE DOOR FRAME IN THE ENTRANCE LOCATED AT APT 2R, 2nd STORY (apt 2R), issued 2007-09-05. HPD violation 4480065
- Class B: Damaged plaster or paint, living room, 2nd floor. REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR WALLS AND CEILING OF LIVING ROOM LOCATED AT APT 2R, 2nd STORY (apt 2R), issued 2007-09-05. HPD violation 4480070
- Class B: Door, lock or intercom defect, 2nd floor. SECTION 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK AT DOOR IN THE ENTRANCE LOCATED AT APT, 2nd STORY, issued 2007-09-05. HPD violation 5273718
- Class B: Broken window or sash, throughout the apartment, 2nd floor. PROPERLY REPAIR THE BROKEN OR DEFECTIVE TOP AND BOTTON SASH ALL WINDOWS IN THE ENTIRE APARTMENT LOCATED AT APT 2R, 2nd STORY (apt 2R), issued 2007-09-05. HPD violation 4480087
- Class B: No heat / heating defect (boiler room). SECTION 27-2010, 2011, 2012 ADM CODE REMOVE THE ACCUMULATION OF REFUSE AND/OR RUBBISH AND MAINTAIN IN A CLEAN CONDITION THE BOILER ROOM AT BOILER ROOM, issued 2007-09-05. HPD violation 4480099
- Class B: No heat / heating defect, living room, 2nd floor. REPLACE WITH NEW THE BROKEN OR DEFECTIVE RADIATOR SHUT -OFF VALVE AT LIVING ROOM LOCATED AT APT 2R, 2nd STORY (apt 2R), issued 2007-09-05. HPD violation 4480079
311 housing complaints
0 in the last 12 months, 2 in 5 years.
Bedbugs
No bedbug filing on record for the last 3 years. HPD's bedbug filings are self-reported by the owner once a year; HPD does not inspect to confirm them.
- 2026: No bedbug filing on record for this year
- 2025: No bedbug filing on record for this year
- 2024: No bedbug filing on record for this year
- 2023: No bedbug filing on record for this year
- 2022: No bedbug filing on record for this year
- 2021: No bedbug filing on record for this year
Buildings department (DOB)
No open DOB violations. 1 DOB violation on record. Check on DOB BIS.
Evictions and housing court
0 executed evictions in the last 3 years (1 on record). 0 open HPD cases; 0 harassment findings.
Rent stabilization
No rent-stabilized units on the tax bill.
Owner and management
Owner: ALLEN AME HOUSING CORP. Head officer: HAROLD FLAKE. Managing agent: ALLEN AME HOUSING CORP. This owner has 2 buildings on record, 2 graded D or F. See the full portfolio.
Last HPD registration Oct 17, 2018. HPD registration expired Sep 1, 2019 and had not been renewed as of Oct 3, 2026. Buildings with 3+ units must register with HPD every year.
Tax lot and city IDs
BBL 4102080025, HPD building ID 679233. HPD Online, ACRIS, DOB BIS.
Nearest subway
- Jamaica Center-Parsons/Archer (E, J, Z), 23 min walk
- Jamaica-179 St (F), 26 min walk
- 169 St (F), 26 min walk
How the grade is calculated
| Factor | On record | Points |
|---|---|---|
| Open HPD violations | 14 open (1 class C, 7 class B, 6 class A). 3 rent-impairing | −45 |
| 311 housing complaints (12 mo) | None | 0 |
| Bedbug reports (3 yr) | None reported | 0 |
| Executed evictions (3 yr) | None | 0 |
| Housing litigation | No open cases | 0 |
| Open DOB violations | None | 0 |
Sources: NYC HPD Housing Maintenance Code Violations, NYC 311 Service Requests, NYC HPD Bedbug Reporting, NYC Marshal Evictions (DOI), NYC HPD Housing Litigations, NYC DOB Violations, NYC DOF tax bills (via JustFix Who Owns What portfolio API, v2), NYC HPD Property Registration. Methodology. Report generated 2026-10-27.